Electrical Load List and Earthing and Lightning Protection
We deliver electrical engineering covering load lists, earthing, lightning protection and explosion protected equipment design
Electrical Load List and Earthing
and Lightning Protection
Electrical engineering for process facilities covers far more than power distribution. Inadequate earthing contributes to static ignition in hazardous areas, undersized lightning protection causes equipment damage and ignition risk, and incorrect explosion protected equipment selection creates non compliance that is expensive to remediate after construction. Our team delivers electrical engineering from the load list through single line diagrams, IEEE 80 earthing design, IEC 62305 lightning protection and full IEC 60079 explosion protected equipment selection, all integrated with the hazardous area classification drawing.

Electrical Load List and Earthing and Lightning Protection workflow
Identify all electrical loads, assign operating/starting duty, demand factors, and power factor by system.
Develop SLD covering switchgear rating, transformer sizing, cable routes, and fault level calculation.
Design earth grid per IEEE 80, calculate step and touch voltages, specify earthing conductor sizing and test points.
Conduct risk assessment per IEC 62305, determine protection level, design LPS with down conductor and SPD specification.
Review area classification drawings, select Ex category, protection concept, and T class per IEC 60079 for each installed item.
Support earthing continuity tests, lightning system inspection, and Ex equipment certification registry.

Every deliverable from basis to handover
Complete Electrical Load List and Earthing and Lightning Protection scope covering every calculation, drawing, specification, and construction support activity.
Outcomes of Electrical Load List and Earthing and Lightning Protection
- We sharpen earthing and lightning protection
- We support hazardous area classification and explosion protected equipment selection
- We reduce electrical incident exposure
- We strengthen grounding for static control
- We maintain compliance with IEEE 80, IEC 62305 and IEC 60079
- We support NFPA 70
- We document explosion protected equipment certification
- We produce documentation that holds up under authority review
- We cut electrical equipment failure
- We harden protection against lightning incidents
- We enable credible load growth
- We improve earthing test programmes
- We right size electrical equipment
- We avoid over specified earthing
- We reduce lifecycle electrical cost
- We support capital cost optimisation
Codes & standards we work to
Triggers that signal the need
Where Electrical Load List and Earthing and Lightning Protection applies
Wellheads, separators, gas compression, FPSO topsides, produced water systems.
Distillation columns, reactors, heat exchangers, storage spheres, LPG handling.
Cryogenic exchangers, liquefaction trains, BOG compressors, storage and sendout.
Reactive systems, batch reactors, solvent handling, runaway reaction scenarios.
Boilers, HRSGs, steam headers, hydrogen systems, ammonia SCR units.
Sterile vessels, CIP/SIP, pressure fermenters, solvent recovery, spray dryers.
Tangible deliverables
- Electrical load list
- Single line diagram
- Earthing design and calculation
- Lightning protection design
- Explosion protected equipment specification
- Cable sizing schedule
Ready to start your project?
Speak with our team to scope an engagement tailored to your facility, regulatory context, and lifecycle stage.