HomeServicesFire & Safety

Fire & Safety

End to end fire engineering — risk assessment, protection design, F&G mapping, suppression, and emergency response.

Strategic context

Why fire & safety matters

Fire & Safety is end-to-end fire engineering — from fire risk assessment through firewater hydraulics, suppression and detection design, egress modelling, and emergency response integration. Our team operates to NFPA 30 / 13 / 11 / 16 / 2001, NBC 2016 Part 4 for India, TAC India, BS 9999 for the UK, FM Global Data Sheets for HPR qualification, and the OISD-STD-117 framework that governs petroleum-sector fire protection in India. Outputs are audit-defensible to AHJ, underwriter, and corporate insurance review.

Fire & Safety
Engagement model

How we deliver

A phased, evidence-led delivery model — from discovery through close-out — built around your facility, regulatory context, and lifecycle stage.

Fire Risk Assessment
Hazard inventory, ignition-source mapping, scenario set linked to FERA / QRA outputs, fire-load characterisation per BS 7974 / NFPA 550.
Active & Passive Protection Design
Sprinkler / foam / gas suppression per NFPA 13 / 11 / 16 / 2001; PFP per API 2218 / UL 1709 / ASTM E119; firewater network per NFPA 24 / 20 / 22.
Detection & Egress
F&G mapping per ISA TR84.00.07 with detector coverage modelling; egress and smoke simulation per Pathfinder / EVACNET against NFPA 101 / NBC 2016 capacity.
Commissioning & ITM Programme
NFPA 25 inspection / testing / maintenance protocol, FM Global walk-down, AHJ submission packs (TAC India / NBC / OISD-117), commissioning flow tests.
Drill & ER Integration
Fire-safety audit cycle, mutual-aid coordination, mock drill design with independent observers, post-drill action register and ERP revalidation.
Outcomes & value

What this service delivers

  • Code-defensible fire protection scope without over-design
  • FM Global HPR-tier qualification with insurance premium savings
  • Firewater system hydraulically validated under credible-worst-case
  • Egress design proven by simulation against ASET / RSET
  • Drill-validated emergency response capability
Why Arborion

Our differentiators

  • NFPA + BS + NBC + OISD code fluency in one engagement
  • FM Global HPR qualification track record across multiple sectors
  • Pipenet / AFT hydraulic modelling capability in-house
  • Pathfinder / EVACNET evacuation simulation experience
Get in touch

Talk to us about fire & safety.

Connect with our team for a consultation scoped to your facility, regulatory context, and lifecycle stage.