Skip to content
ISO 45001 Occupational Health and Safety Management System

Performance Evaluation

We run monitoring, measurement and analysis, the internal audit and the management review

Strategic context

What this element is and why it matters

Clause 9 is the assurance layer of the standard. It covers monitoring, measurement, analysis and performance evaluation in clause 9.1, the internal audit to ISO 19011 in clause 9.2, and the management review in clause 9.3. The clause provides the feedback that drives the improvement of clause 10 and re informs the design of clauses 4 through 8. Without rigorous execution of clause 9 the management system quietly drifts.

Performance Evaluation

Individual significance for organisations

Clause 9 is where your organisation either learns what is working or stays blind to drift. Facilities with disciplined performance evaluation, rigorous audit programmes and a substantive management review keep improving, while sites where clause 9 is reduced to checkbox compliance accumulate hidden problems until an incident surfaces them.

Contribution to ISO 45001 Occupational Health and Safety Management System

Clause 9 closes the management system loop. It provides the feedback that the improvement of clause 10 acts on, the assurance that the design across clauses 4 through 8 is genuinely delivering, and the evidence that the leadership of clause 5 uses for governance decisions. The management review in clause 9.3 is the apex governance event where the whole system is assessed each year.

Key requirements

What compliant execution looks like

Monitoring, measurement and analysis to clause 9.1.1
Evaluation of compliance to clause 9.1.2 against legal and other requirements
An internal audit to clause 9.2 covering the programme and its execution to ISO 19011
A management review to clause 9.3 with defined inputs, outputs and an action register
Integration with API RP 754 process safety event indicators and your corporate ESG reporting
Documentation that withstands certification body surveillance and the scrutiny of regulators and insurers
Implementation methodology

How we implement this element

A focused six step methodology calibrated to deliver performance evaluation as a working capability rather than a documented compliance artefact.

Monitoring and Measurement to Cl.9.1.1

We establish what to monitor and measure, the methods, when to measure, when to analyse and when to evaluate, and we align it all with your health and safety objectives and operational risk.

Compliance Evaluation to Cl.9.1.2

We evaluate compliance periodically against the legal and other requirements identified in clause 6.1.3, we document the results, we retain the evidence under clause 7.5, and we trigger corrective action under clause 10 wherever a gap appears.

Internal Audit Programme to Cl.9.2

We build a programme that covers every requirement of the management system, we secure auditor competence and independence to ISO 19011, we work to a protocol clause by clause, and we categorise and track findings to closure.

Management Review to Cl.9.3

We facilitate an annual review with the mandatory inputs of audit results, compliance evaluation, health and safety objectives, incidents, communication and opportunities for improvement, and we document the outputs and actions.

Process Safety Event Indicator Integration

We integrate your ISO 45001 key performance indicators with API RP 754 process safety event indicators, your corporate ESG, TCFD and BRSR reporting, and ICCA peer survey participation where it applies.

Certification Surveillance

We maintain documentation that holds up under certification body Stage 1, Stage 2 and surveillance audits with DNV, BV, BSI or TUV, and we prepare you for the triennial recertification cycle.

Implementation flow

Element implementation flow chart

A decision gated workflow that shows the actual sequence of activities from initiation through steady state operation, with key decision points highlighted.

Start
Clauses 4 through 8 in operation and generating performance data
Monitoring and Measurement to Cl.9.1.1
Methods, frequency and analysis approach
Compliance Evaluation to Cl.9.1.2
Against legal and other requirements
Decision
Compliance Gap?
Decision gate
Corrective Action Trigger to Cl.10
Through the non conformance procedure
Internal Audit to Cl.9.2
Auditor competence, protocol and finding categorisation
Audit Report and Findings Register
Critical, major and minor findings with owner and close out
Management Review to Cl.9.3
Annual review with mandatory inputs and decisions
Indicator Integration
API RP 754 with ESG, TCFD and BRSR reporting
Certification Surveillance
External audit at Stage 1, Stage 2, surveillance and recertification
Deliverables

What we produce

  • A monitoring and measurement plan to clause 9.1.1
  • A compliance evaluation procedure to clause 9.1.2
  • An internal audit programme with a competency framework to clause 9.2
  • A management review protocol to clause 9.3
  • Integration of process safety event indicators with your corporate reporting
  • A certification surveillance preparation pack
Common pitfalls

Where execution fails

  • Monitoring without analysis so data accumulates without any insight
  • An internal audit run by the very department being audited, with no independence
  • A management review treated as a rubber stamp
  • Findings filed but never closed
Standards & references

Codes this element is built on

ISO 45001 from 2018 Cl.9 (Performance Evaluation)ISO 19011 from 2018 (Auditing Management Systems)API RP 754 (Process Safety Event Indicators)Annex SL Cl.9 (parallel structure)ISO 17021 (Certification Body Requirements)Corporate ESG, TCFD and BRSR frameworks
All elements in this framework

ISO 45001 Occupational Health and Safety Management System full element index

Implement this element

Talk to us about implementing Performance Evaluation

We can scope this element implementation against your facility, regulatory context, and existing management system maturity, then integrate it with the other ISO 45001 Occupational Health and Safety Management System elements you already operate.